[MIX_TEMP]
±3°C

Aggregate discharge temperature held within ±3°C — preventing brittle mix and binder stripping.

[NO_COKING]
Zero cont.

No direct flame on bitumen — eliminates coking, oxidation, and fire risk at storage tanks.

[OUTPUT]
750–2500
kW Heat Output

Single and double-burner configurations for drum dryers, storage tanks, and bitumen transfer heating.

Transport
Process
Heating

Indirect process heating for asphalt mixing plants and bitumen storage.

Purpose-built indirect process heaters for transport infrastructure applications. From rotary drum dryers in asphalt mixing plants to bitumen storage tank heating — precise, contamination-free thermal energy with 20+ year service life.

[APPLICATIONS]

Transport
Applications

Select an application to see how our process heaters address your specific transport infrastructure heating needs.

Asphalt mix quality is set in the drum dryer. Moisture left in the aggregate causes foaming at the pugmill and premature stripping on the road surface. Temperature overshoot oxidises the binder and produces brittle pavement that cracks within two winters. Our indirect process heaters deliver 750–2,500 kW of precise, modulating thermal output to rotary drum dryers and parallel-flow mixing drums — holding aggregate discharge temperature within ±3°C of target across variable feed moisture and gradation.

Output Range
750–2500kW
Drum dryer heating
Discharge Temp
±3°C
Aggregate target
Fuel Options
Multi
Gas / LPG / Biogas

Indirect Heating

No flame contact with binder or aggregate

Multi-Fuel Ready

Natural gas, LPG, biogas flexibility

Smart Controls

Modulating burners with PLC automation

20+ Year Life

Free-floating tube bundle design

[WHY_INDIRECT_HEAT]

Built for
Transport Infrastructure

Key advantages of indirect process heaters for asphalt production and bitumen handling operations.

EcoHeat process heater for transport industry asphalt and bitumen applications
EcoHeat Process Heater750 – 2500 kW

No Direct Flame on Binder

Indirect heat exchange keeps combustion gases and open flame away from bitumen — eliminating coking, oxidation, and fire risk at the tank or drum.

Precise Aggregate Temperature

Modulating burners hold drum dryer discharge within ±3°C of target — preventing moisture retention, binder stripping, and brittle mix from overheated aggregate.

750 kW to 2500 kW Output

Single and double-burner EcoHeat configurations scale from small batch plants to continuous high-throughput drum mixing operations producing 300+ t/h.

Multi-Fuel Flexibility

Natural gas, LPG, or biogas — switch fuel source to match site infrastructure. No burner modifications required, reducing operational costs and carbon footprint.

20+ Year Service Life

Free-floating tube bundle absorbs continuous thermal cycling without stress cracking — engineered for the harsh, dusty, 24/7 environment of asphalt production.

Rapid Startup & Load Response

Cold to full output in ~30 minutes. Modulating controls respond in seconds to feed moisture and gradation changes — no production gaps between loads.

[HOW_IT_WORKS]

Built to Fit
Your Operation

Drop-in heat source for your existing asphalt drum dryer or bitumen storage tank — standard connections, minimal downtime.

[WHY_IT_MATTERS]

Wrong Temperature.
Failed Core.
Ripped-Up Road.

Aggregate discharged too cold traps moisture — the mix foams at the pugmill and strips on the road within one winter. Too hot, and the binder oxidises into a brittle film that cracks under traffic loading. At the tank, a 10°C overshoot cokes bitumen onto the heating surface and degrades the polymer modifier. EcoHeat indirect heaters hold every temperature set-point within specification — from drum discharge to tank storage — with zero direct flame on the product.

Spec a Transport Heater
Moisture retention in aggregate causing mix foaming

Modulating heat output ensures aggregate reaches target discharge temperature every time — driving off residual moisture before it reaches the pugmill.

Bitumen coking and oxidation in storage tanks

Indirect heating eliminates local hot spots on tank shells and coils — maintaining binder viscosity and polymer properties without coking or fume generation.

Inconsistent mix temperature across production shifts

Fast-responding modulating controls compensate for feed moisture and gradation changes in seconds — delivering consistent mix temperature to the truck, load after load.

Inconsistent mix temperature across production shifts

Fast-responding modulating controls compensate for feed moisture and gradation changes in seconds — delivering consistent mix temperature to the truck, load after load.

Industrial rotary dryer with Enertherm EcoHeat indirect process heater integrated at the heat inlet — 3D CAD render showing stainless steel drum, support frame, and heater connection point for asphalt and bitumen applications
[TECHNICAL_DOCUMENTS]Download Brochures
[TRANSPORT_FAQ]

Transport
FAQs

Common questions about using indirect process heaters for asphalt mixing and bitumen heating applications.

TRANSPORT ENQUIRY

Transport
Consultation

Our engineering team specialises in transport infrastructure thermal solutions. Tell us about your asphalt plant or bitumen heating requirements.

  • Asphalt drum dryer heating
  • Bitumen storage tank heating
  • Transfer line temperature maintenance
  • Retrofit & integration planning
Response Time
Next Working Day

Transport ENQUIRY

Fill out the form below. * Required fields