Skip to main content
Return to Resources
Energy Efficiency Strategies: Target 20-30% Baseload Waste

Energy Efficiency Strategies: Target 20-30% Baseload Waste

Published
Est. Read14 min read

How ISO 50001 and PLC monitoring expose non-production energy waste

Baseload energy waste is the utility demand that continues when a manufacturing site is not producing, cleaning, warming up or carrying out an essential controlled process. For plant managers, a sensible first target is to investigate whether 20–30% of apparent baseload demand can be removed through operating controls, maintenance and verified shutdown routines.

This is an investigation target, not a universal saving promise. A food factory with refrigeration and hygiene duties will have a different non-production profile from a batch chemical plant, metal fabricator or pharmaceutical site. Some overnight demand protects product, maintains environmental conditions or preserves process readiness. Other demand comes from equipment left running through routine, unclear ownership, leakage or inappropriate control settings.

The practical question is straightforward: what is consuming electricity, gas, steam, compressed air, water or oil when no product is leaving the line?

A whole-site utility bill cannot answer that question. It records consumption but does not connect demand to equipment, shifts, batches, line status or planned shutdowns. Effective energy-efficiency strategies start by mapping consumption to the operational state that caused it.

Why baseload waste matters in manufacturing

Why baseload waste matters in manufacturing

Baseload is often treated as an unavoidable fixed cost. In reality, it contains necessary and avoidable demand. The task is to separate the two with evidence.

A site may need to maintain cold storage, frost protection, critical ventilation, security systems, environmental controls or a defined standby temperature. These loads need documented operating reasons, owners and acceptable limits.

Avoidable demand often appears in less obvious places:

  • Compressed-air compressors cycling to maintain pressure through leakage or idle pneumatic demand
  • Extraction fans operating at full speed after production has ended
  • Pumps circulating water, thermal fluid or chilled water with no process call
  • Boilers or steam systems held above the required standby condition
  • Dust collection equipment operating without the connected process line
  • Lighting, local heaters or cooling units left on in unoccupied areas
  • Idle production equipment remaining energised between batches or over weekends

A sustained non-production load can be expensive because it runs for long periods. A marginally inefficient motor operating for 24 hours creates a different cost profile from the same motor operating only during a planned production shift.

Baseload also gives plant teams a clear operational measure. Production volume, recipe changes and product mix can complicate daytime energy analysis. During a comparable weekend closure, the question is narrower: which loads remained active, and did they need to?

Omni Vision
// SOLUTION
Omni Vision.

Omni Vision delivers turnkey utility metering, CO2 tracking, and AI-powered production KPI intelligence — giving you real-time dashboards and actionable insights across your entire facility.

Energy consumption mapping exposes hidden demand

Energy consumption mapping links utility data to the assets, areas and production states that explain it. It gives plant managers a route from an unexplained site total to a prioritised action list.

Map the six core utility streams

A useful plant map covers electricity, gas, water, steam, compressed air and oil where it forms part of the operation. Start with incoming utility meters, then move towards major plant rooms, production areas and significant energy users.

Utility streamBaseload questionLikely areas for investigation
ElectricityWhat remains energised outside operating hours?Compressors, motors, fans, refrigeration, lighting and standby equipment
GasIs fuel use necessary during shutdown?Boilers, ovens, process heating and space heating
SteamWhat requires steam pressure to remain available?Distribution losses, tracing, condensate systems and equipment on standby
Compressed airWhy does the system continue cycling?Leaks, open blow-offs, idle machines and unsuitable end uses
WaterWhy is flow continuing without production or cleaning?Leakage, cooling circuits, uncontrolled flushing and washdown
OilDoes thermal-fluid or fuel demand match the schedule?Heat loss, circulation pumps and unnecessary heating periods

Site-level data remains valuable for billing and energy procurement, but it is rarely enough for operational control. An area-level or line-level view can show whether utility demand follows a batch schedule, machine state, output level or maintenance event.

Match demand to production states

Energy data gains value when it uses the same time reference as production data. Plant managers should map each significant load against defined operating states:

  1. Production running
  2. Changeover
  3. Cleaning or washdown
  4. Short stop
  5. Planned shutdown
  6. Weekend or holiday closure
  7. Start-up and warm-up

This prevents false conclusions. High electricity demand may be legitimate during refrigeration pull-down, clean-in-place activity or a controlled heat-up. The same demand during an empty weekend calls for investigation.

The same logic applies to performance indicators. kWh per tonne, kWh per batch, steam per batch, compressed-air use per operating hour and energy cost per production unit can reveal trends that a single site total conceals. A plant with variable product formats should compare similar products, recipes and line conditions rather than forcing all output into one benchmark.

Establish the technical minimum

A baseload figure should not be guessed from the lowest point on a dashboard. The lowest recorded demand may reflect a holiday closure, an outage or weather conditions that cannot be repeated.

Instead, identify the technical minimum required for safe and compliant non-production operation. Document the assets that must remain live, their expected consumption and the reason for each exception. This creates a defensible non-production baseline.

Once that baseline exists, unexplained demand becomes easier to identify. A weekend electricity load above the agreed technical minimum may indicate a compressor cycling, an air-handling unit running outside its schedule or a production support system that has not shut down correctly.

How plant managers can find 20–30% baseload waste

How plant managers can find 20–30% baseload waste

The first stage is measurement. The second is a controlled operational trial. Teams should not isolate equipment solely because it looks inactive on a trend chart. Quality, safety, maintenance and process requirements must define the safe limits.

Build a non-production load profile

Collect interval utility data over several weeks. The dataset should include a normal production day, overnight shutdowns, planned weekend closures and longer non-production periods where available.

Fifteen-minute or half-hourly readings can reveal broad baseload patterns. Higher-frequency data may be needed where rapid cycling, short stops or compressor loading patterns are material.

Review the profile against the production schedule for these warning signs:

  • Overnight demand close to daytime consumption
  • Utility demand rising after production has stopped
  • Repeated compressor starts during a closed period
  • Gas or steam consumption continuing after thermal processes have finished
  • Water flow with no scheduled cleaning, cooling or hygiene activity
  • A Monday start-up peak that suggests equipment ran unnecessarily throughout the weekend

The investigation should identify the responsible asset, its normal operating state, the accountable person and the physical reason it remains active.

Run a controlled shutdown trial

A planned weekend shutdown trial is a useful diagnostic exercise. Production, engineering, maintenance, quality and health and safety teams should agree the plan before any change occurs.

The trial should record:

  • Assets that must remain live and the reason for each one
  • Assets suitable for controlled isolation
  • Lock-off, restart and inspection requirements
  • Temperature, humidity, pressure and product-protection limits
  • Named owners for equipment groups
  • The meter points and operating records used to verify results

The result should define the site’s minimum safe demand. It can also expose equipment with unclear ownership. A compressor that continues to cycle overnight might indicate leakage, an open drain, a forgotten pneumatic connection or demand from another area of the factory.

Prioritise actions with low production risk

Early interventions often involve control settings, schedules, leaks and maintenance. They are easier to test than large capital projects and provide evidence for further investment.

Common measures include:

  • Timed shutdown of non-essential auxiliaries
  • Compressor leak detection and repair
  • Compressor pressure-setpoint review
  • Fan scheduling and speed reduction where the process permits
  • Demand-controlled ventilation
  • Pump scheduling based on genuine process demand
  • Boiler and steam standby review
  • Repairs to damaged insulation
  • Removal of inappropriate compressed-air uses
  • Clear shutdown checklists for lines and support areas

Government guidance on industrial efficiency also identifies measures such as reviewing ventilation time settings, turning equipment off when it is not in use, improving auxiliary equipment control and maintaining refrigeration equipment.

The operating requirement comes first. A thermal process may need a controlled standby condition to protect equipment, maintain product integrity or achieve a reliable restart. The objective is to establish the lowest safe and productive standby state.

Omni Vision
// SOLUTION
Omni Vision.

Track energy consumption, emissions, and process parameters with seamless PLC/SCADA integration via Modbus, OPC-UA, and MQTT protocols.

Production KPIs turn energy data into operational evidence

A plant manager needs more than an energy total to determine whether performance has improved. Production-linked KPIs show whether a utility change reflects waste removal, lower output or a different production mix.

Choose KPIs that match the process

The appropriate KPI depends on how the plant produces value. A continuous process may use kWh per tonne. A batch facility may use energy per batch. A packaging line may use kWh per thousand units. A utility-intensive process may track steam per batch or compressed-air consumption per operating hour.

The denominator must reflect real operating activity. Headcount and floor area may help explain building demand, but they usually provide weak measures of manufacturing process efficiency.

Useful production-linked KPIs include:

Operational questionSuitable KPI
Has a line become more efficient at the same output?kWh per tonne or kWh per production unit
Has batch energy reduced after an operating change?kWh per batch
Is compressed air being used outside production?m³ per operating hour or demand during non-production periods
Has thermal demand changed with product mix?Steam or gas per batch, recipe or product family
Which shift has unexplained energy variation?Energy per unit by shift under comparable conditions

A KPI becomes useful only when the plant defines the comparison conditions. A high energy-per-tonne result may be expected for a short run, difficult recipe, heat-up cycle or reduced line speed. The investigation should distinguish these legitimate drivers from avoidable consumption.

Use exception management rather than retrospective reports

Monthly reporting can identify a broad trend, but it often arrives too late for operational correction. A stronger approach defines expected demand by production state and flags exceptions as they occur.

For example, a compressed-air profile that stays elevated after a line changes to “stopped” can prompt an engineering inspection. A steam load that remains high after a batch completes can direct attention towards tracing, isolation, steam traps or boiler controls. A refrigeration load that fails to fall during an expected low-demand period can prompt a review of door management, defrost scheduling or equipment condition.

The pattern identifies where to inspect. Engineers still need to confirm the physical cause at the asset.

Efficiency ROI analysis for energy actions

Efficiency ROI analysis for energy actions

Efficiency ROI analysis allows plant managers to rank potential actions using consistent financial and operational criteria. It prevents a low-cost idea with uncertain savings from taking priority over a well-defined measure with a short, verifiable payback.

Define the full investment cost

Investment cost should include more than the purchase price of equipment. It may include design, installation labour, production downtime, control changes, commissioning, training, validation, temporary plant and project management.

For a compressed-air leak programme, the cost may cover survey work, repair labour, replacement parts and follow-up testing. For a controls project, it may include programming, commissioning and documentation as well as hardware.

A complete cost estimate avoids overstating the return from an apparently inexpensive measure.

Measure annual energy and cost savings

Annual energy savings should come from measured pre-change and post-change conditions, adjusted for relevant production variables. For a baseload action, comparable overnight periods or weekend shutdowns often provide the clearest evidence.

Measured annual cost saving should reflect the tariff actually affected by the reduction. Electricity demand charges, unit rates, fuel cost and avoided maintenance can have different financial effects. A project that lowers kWh but has no material effect on the relevant tariff needs a different business case from one that reduces both consumption and peak demand.

The analysis should state the assumptions behind any annualisation. A one-week trial during a summer shutdown may not represent a full operating year.

Include maintenance and production effects

Maintenance impact belongs in the business case. Reduced compressed-air leakage may lower compressor run hours and maintenance demand. A lower boiler standby condition may reduce fuel use but increase start-up time. A fan schedule may cut electricity use but require checks that ventilation remains adequate for the process.

Plant managers should record both positive and negative operational effects:

  • Changes to maintenance hours or component life
  • Start-up time and readiness requirements
  • Product-quality or hygiene controls
  • Risks of lost production time
  • Process safety requirements
  • Changes to operator workload

A technically sound action must protect throughput, quality and safety as well as reduce energy use.

Agree payback and the verification period before approval

Payback period compares the project cost with the expected annual cost saving. It is a practical screening measure, but it should not replace verification.

Before work begins, agree the verification period, baseline data, responsible owner and acceptance criteria. A short operational change may be checked over several comparable shutdowns. A seasonal heating or refrigeration project may require a longer period to account for weather and operating variation.

This agreement protects the project after installation. It also records what the site expected to achieve, what it achieved and which conditions affected the result.

ISO 50001:2018 makes improvement repeatable

ISO 50001:2018 sets out a framework for establishing, implementing, maintaining and improving an energy management system. It follows the Plan-Do-Check-Act cycle, which suits manufacturing baseload reduction because it turns a shutdown exercise into a managed operating routine.

Plan: identify significant uses and establish the baseline

The planning stage identifies energy sources, significant energy uses, legal and operational requirements, relevant variables and energy performance indicators. For a manufacturing site, the baseline should record output, product type, operating hours, cleaning schedules, ambient conditions and other factors that influence demand.

For baseload work, the plan should define the technical minimum for non-production periods and list approved exceptions.

Do: embed controls in daily work

The implementation stage assigns actions to people and procedures. Shutdown checklists, leak-repair programmes, operating schedules and preventive maintenance tasks need clear ownership.

EnerTherm Engineering’s Omni Vision Energy Intelligence Platform combines metered utility data with production information. Its stated manufacturing workflow covers electricity, gas, water, steam, compressed air and oil, then associates consumption with lines, shifts and batches. Read-only PLC connectivity provides machine-state context without writing to plant control systems. It allows teams to compare expected and actual non-production demand.

The platform does not replace site inspection. It provides time-stamped evidence that directs engineering attention towards a specific area, line or operating period.

Check and act: verify savings, then prevent drift

The checking stage compares measured results with the agreed baseline and KPI. For baseload actions, equivalent closed periods provide strong evidence, provided the team records outages, weather effects and unusual operating conditions.

The acting stage turns confirmed gains into routine practice. Operators and building-management systems can apply validated changes during approved change windows. Teams should update shutdown procedures, set exception thresholds, assign response owners and review trends regularly. If weekend demand rises again, the plant can investigate the deviation before it becomes an accepted overhead.


This article reflects the independent analysis and editorial opinion of EnerTherm Engineering. Product names, trademarks, and brands mentioned belong to their respective owners. EnerTherm Engineering is not affiliated with, endorsed by, or a licensee of any third-party software or product mentioned unless explicitly stated.

[ABOUT THE AUTHOR]
Masab Javed
Masab Javed

Senior Process Engineer — EnerTherm Engineering

Masab Javed is a Senior Process Engineer at EnerTherm Engineering with extensive expertise in chemical process design, decarbonisation, and sustainable industrial solutions. He holds an MSc from TUM School of Management and a BEng in Chemical Engineering from NUST, with experience spanning ammonia production, CO2 capture, and semiconductor manufacturing optimisation.

Chemical Process Engineering & DesignPre-FEED & Front End Engineering Design (FEED)Industrial Decarbonisation & Net-Zero StrategyCO2 Capture & Hydrogen Production Modelling